Agenda Item
· Los Angeles
PLUM — Item 2
Original agenda text
Item
(2)
24-1609
CD 3
Mitigated Negative Declaration (MND), No. ENV-2022-8611-MND, pursuant to
California Environmental Quality Act (CEQA) Guidelines, Sections 15162 and
15164, and related Environmental findings; report from the Los Angeles City
Planning Commission (LACPC), a draft Ordinance effectuating a Zone Change
and Height District Change from C4-1LD and P-1LD to (T)C2-2; and an appeal
filed by West Valley Alliance for Optimal Living (Representative: Jamie T. Hall,
Channel Law Group, LLP) from the LACPC’s determination in: 1) approving
pursuant to the Los Angeles Municipal Code (LAMC) Section 11.5.7 F, Specific
Plan Exceptions from the Ventura/Cahuenga Boulevard Corridor Specific Plan
(Ordinance No. 166560) in conjunction with the development of a self-storage
building to permit: Self-storage site (Parcel A): a) 112,204 square feet of floor
area in lieu of 40,024 square feet permitted for a 3.7:1 Floor Area Ratio (FAR)
in lieu of a 1.25:1 FAR permitted in Section 6.B.1.a; b) 80 feet four inches in
height in lieu of 45 feet as permitted in the Specific Plan Section 7.E 1.e.3; and
c) Zero feet landscape buffer in lieu of 10 feet along Clarendon Street and six
feet 11 inches in lieu of 10 feet along Alhama Drive as required in Specific Plan
Section 7.D 1.b; Hotel Site (Parcel B): a) Zero feet landscape buffer in lieu of
10 feet along Alhama Drive and four feet landscape buffer in lieu of 10 feet
along Ventura Boulevard as required in Specific Plan Section 7.D 1.b; and b)
95 parking spaces in lieu of 134 parking spaces as permitted in the Specific
Plan Section 7.F.1.d; 2) approving, pursuant to LAMC Section 11.5.7 C, and
Section 9 of the Ventura/Cahuenga Boulevard Corridor Specific Plan, a
Specific Plan Project Permit Compliance Review to permit the construction of a
self-storage facility with an associated office space and the relocation of a
swimming pool at an existing hotel; 3) approving, pursuant to LAMC Section
12.24 W.50, a Conditional Use to allow for the development of a storage
building for household goods within 500 feet of a residential use; 4) approving,
pursuant to LAMC Section 12.24 S, a Conditional Use to allow up to 20 percent
parking reduction for the storage building, otherwise required by LAMC; and 5)
approving, pursuant to LAMC Section 16.05, a Site Plan Review for a
development of a project resulting in a net increase of 50,000 square feet of
nonresidential floor area; for the minor improvements to an existing hotel on
the site, including the configuration of hotel parking areas, demolition of the
existing hotel swimming pool, and construction, use, and maintenance of a new
pool and ancillary structures to the eastern portion of the hotel project site and
a six-story, 112,204-square foot self-storage facility, including approximately
111,173 square feet of self-storage for household goods with an 804-square
foot associated office and support space, with loading areas, and surface
parking, the self-storage building will be a maximum of 80 feet four inches, as
measured from grade to the top of the roof structure with a maximum FAR of
3.7:1, the project includes 95 vehicle parking spaces for the hotel site and 29
parking spaces for the self-storage building site to be provided in surface
parking lots located on the project site, additionally, the project includes 16
short-term bicycle parking spaces and 16 long-term bicycle parking spaces; for
the property located at 21101 West Ventura Boulevard, subject to Conditions of
Approval; and adoption of project findings.
Applicant: Mike Gallen, Johnson Development Associates, Inc
Representative: Sara Houghton, Three6ixty
Case No. CPC-2022-8609-ZC-HD-SPE-SPP-CU-SPR
Environmental No. ENV-2022-8611-MND
Related Case: AA-2022-8610-PMLA
Fiscal Impact Statement: Yes